Product Details
Product Details
1.Inspection of lock opening and closing times: lock opening and closing times≥ 200000 times.
2. Power requirements: Lock power ≤ 24V DC.
3. Current requirement: impulse current ≤ 5A at the moment of opening and closing, and current ≤ 500mA.
4. Response time: unlocking response time ≤ 2S, continuous power 7S should not be damaged.
5. Shell temperature: Shell temperature ≤ 65 ℃.
6. Security level: The security level of the bolt meets the B- level requirements in the GA374-2019.
7. motor lock reliability test: under normal conditions, continuous normal opening and closing 200000 times can still work normally.
8. Standby unlocking: When the electronic opening fails, the emergency mechanical opening key can be used to directly open the cabinet door. The gun cabinet will give an on-site alarm at the same time, and the cabinet can be opened through the main cabinet control. The password token of the emergency mechanical opening key can be kept by two people, which can meet the requirements of double lock. When the cabinet body is strongly damaged and abnormal technology is opened, the cabinet itself can send out on-site alarm.
Previous article
Next article
Previous article
Next article
recommend Products